| 1 | Profile A | Lift-and-slide doors, slim sliding windows, fixed panoramic units | Thermally broken aluminum; multi-chamber profiles; concealed drainage | Double or triple insulating glass; Low-E; laminated and tempered glass | CAD-based shop drawings, non-standard sizes, corner glazing, hardware upgrades | Typical U-value target: 1.0–2.0 W/m²K, depending on glass and frame; weather seals for residential exposure | Powder coatingAnodizingWood-look coating | Incoming aluminum and glass inspection; dimensional checks; drainage and hardware testing | Applicable testing commonly includes EN 12207, EN 12208, EN 12210, ASTM E283, ASTM E331 and ASTM E330; ISO 9001 may be requested for the supplying factory |
| 2 | Profile B | Casement windows, French doors, bi-fold doors, tilt-and-turn windows | Thermally broken profiles with polyamide insulation strips; European-style hardware compatibility | Double glazing, acoustic laminated glass, solar-control Low-E glass | Opening direction, mullion layout, hardware color, insect screens and integrated blinds | Designed for improved air tightness and resistance to wind-driven rain; performance depends on engineering and installation | RAL powder coatingAnodizedFluorocarbon coating | Profile wall-thickness verification; glass edge inspection; assembly and water-tightness checks | Common project references use EN 14351-1, EN 12207, EN 12208, EN 12210 and CE-related documentation where applicable |
| 3 | Profile C | Minimal-frame sliding doors, fixed windows, villa entrance doors | Large-format thermally broken sliding systems; reinforced meeting stiles | Insulating glass units up to approximately 30–40 mm overall thickness, subject to system design | Extra-wide panels, recessed tracks, custom thresholds, security cylinders and pull handles | Project-specific structural calculation is required for large spans; glazing selection affects acoustic and thermal results | Matt powder coatAnodizedDual-color finish | Load-bearing hardware checks; roller adjustment; panel alignment; packaging inspection | Typical verification may reference EN 12210, EN 12207, EN 12208, ASTM E330 and ASTM E331; certification scope must be checked per product line |
| 4 | Profile D | Thermal-break casement windows, awning windows, hinged balcony doors | Multi-point locking aluminum systems with thermal isolators and EPDM gaskets | Clear, tinted, Low-E, tempered, laminated and fire-rated glass options where approved | Custom transoms, ventilation openings, safety restrictors, screens and color matching | Suitable performance must be confirmed through air, water and wind testing for the selected configuration | Powder coatingAnodizingPVDF option | Batch traceability; coating thickness checks; corner-joint and sealant inspection | Relevant standards can include EN 14351-1, EN 12207, EN 12208, EN 12210 and ISO 9001 quality-management documentation |
| 5 | Profile E | Bi-fold doors, sliding doors, corner systems and large fixed glazing | Thermally broken folding and sliding systems with stainless-steel or heavy-duty roller options | Tempered double glazing, laminated safety glass, acoustic glass and solar-control glass | Panel configuration, stacking arrangement, sill type, handle design and threshold accessibility | Large openings require structural wind-load calculations and approved glass make-up; drainage design is critical | Marine-grade anodizingPowder coatingWood effect | Operating-cycle checks; roller load inspection; seal continuity and water drainage testing | Product testing is commonly aligned with EN 12207, EN 12208, EN 12210, ASTM E283 and ASTM E331; project certification varies |
| 6 | Profile F | Aluminum louver windows, clerestory windows, casement and sliding units | Standard and thermally improved aluminum profiles; optional integrated sun-shading components | Insulating glass, obscure glass, laminated glass and ventilation-compatible glazing | Ventilation modules, privacy glass, motorized controls, custom louvers and project-specific colors | Solar-control and ventilation performance depend on louver geometry, glass specification and control strategy | Powder coatingAnodizedCustom color | Blade alignment; actuator testing where applicable; coating and fastener inspection | Applicable references may include EN 14351-1, EN 12207, EN 12208, EN 12210 and relevant electrical standards for motorized systems |
| 7 | Profile G | Thermal-break entrance doors, pivot doors, French doors and sidelights | Reinforced aluminum door frames; multi-point locks; adjustable hinges | Tempered, laminated, decorative, Low-E and insulated safety glass | Door leaf thickness, pivot position, access-control preparation, threshold and hardware selection | Security, air permeability, water tightness and wind resistance depend on door construction and hardware configuration | Powder coatingAnodizingPVDF coating | Lock and hinge load checks; leaf-to-frame gap inspection; final opening and closing tests | Common references include EN 14351-1, EN 12207, EN 12208, EN 12210 and applicable door-hardware standards |
| 8 | Profile H | Economical sliding windows, balcony doors and standard casement windows | Aluminum systems with optional thermal-break upgrades; standard and heavy-duty sliding tracks | Single glass for limited applications; double glazing; tempered and tinted glass | Standard modular sizes, grille patterns, screen doors, hardware colors and basic custom dimensions | Performance varies widely by system; thermal-break profiles and insulating glass are recommended for conditioned villas | Powder coatingAnodizing | Material identification; section-size checks; glass thickness and hardware-function inspection | Potential test references include EN 12207, EN 12208, EN 12210, ASTM E283 and ASTM E331; exact reports should be requested |
| 9 | Profile I | High-performance casement windows, tilt-and-turn units and terrace doors | Thermally broken profiles with continuous central gaskets and multi-point locking | Triple glazing, warm-edge spacers, acoustic laminated glass and safety glazing | Passive-house-oriented configurations, custom mullions, hardware integration and energy calculations | Low-U-value designs are possible with suitable frame, spacer and glass combinations; whole-window calculation is required | Low-gloss powder coatAnodizingDual finish | Thermal-break placement checks; gasket continuity; hardware adjustment; sample-window testing | Relevant documentation may include EN 14351-1, EN 12207, EN 12208, EN 12210, ISO 10077 and ISO 9001 records |
| 10 | Profile J | Custom curtain-wall-style villa glazing, skylights, sliding doors and fixed façades | Thermally improved framing; reinforced transoms and mullions; customized drainage paths | Double or triple insulating glass, laminated safety glass, solar-control and bird-safe glass options | Façade interfaces, skylight angles, structural connections, custom flashings and mixed systems | Requires project-specific structural, thermal, condensation and drainage assessment, especially for skylights and façades | Powder coatingAnodizingPVDF coating | Engineering review; shop-drawing approval; mock-up inspection; sealant, flashing and drainage checks | Possible references include EN 13830, EN 14351-1, EN 12152, EN 12154, ASTM E283, ASTM E331 and ASTM E330 |