| Supplier Profile 1 | Current-limiting fuse links for distribution-transformer protection | Common classes include 3.6, 7.2, 12, 24 and 40.5 kV | IEC 60282-1; applicable GB/T 15166 series requirements | Rated current options, breaking capacity, time-current characteristics and striker options | Type-test reports, fuse-link curves and rated breaking-capacity documentation |
| Supplier Profile 2 | Expulsion fuse cutouts and replaceable fuse links for outdoor distribution systems | Common classes include 12, 24 and 36 kV | IEC 60282-2; applicable GB/T 15166 series requirements | Insulation level, interrupting performance, creepage distance and mechanical endurance | Routine-test records, insulation test data and environmental ratings |
| Supplier Profile 3 | High-voltage fuse assemblies intended for use with transformer-switchgear combinations | Common classes include 7.2, 12, 24 and 40.5 kV | IEC 60282-1 or IEC 60282-2, according to fuse type; relevant switchgear standards as applicable | Coordination with switching devices, striker compatibility and installation clearances | Coordination studies, assembly drawings and compatibility declarations |
| Supplier Profile 4 | Indoor current-limiting fuse links for compact transformer substations | Common classes include 3.6, 7.2, 12 and 24 kV | IEC 60282-1; applicable national requirements | Compact dimensions, thermal performance and compatibility with enclosed fuse holders | Dimensional drawings, temperature-rise data and holder compatibility details |
| Supplier Profile 5 | Outdoor fuse cutouts and distribution fuse links | Common classes include 12, 24 and 36 kV | IEC 60282-2; applicable national requirements | Outdoor insulation performance, corrosion resistance and operation under specified conditions | Material specifications, pollution-class information and outdoor test reports |
| Supplier Profile 6 | Transformer fuse links with multiple rated-current selections | Common classes include 7.2, 12, 24 and 40.5 kV | IEC 60282-1; applicable GB/T 15166 series requirements | Current-range coverage, minimum breaking current and load-versus-fault coordination | Published time-current curves and application guidance for transformer protection |
| Supplier Profile 7 | Expulsion fuse links and associated fuse-cutout components | Common classes include 12, 24 and 36 kV | IEC 60282-2; applicable GB/T 15166 series requirements | Link replacement options, mechanical fit and compatibility with the specified cutout | Interchangeability details, product drawings and component test records |
| Supplier Profile 8 | Current-limiting fuse links for indoor and enclosed applications | Common classes include 3.6, 7.2, 12 and 24 kV | IEC 60282-1; applicable national requirements | Arc-energy limitation, fuse-holder fit and performance within the intended enclosure | Breaking-capacity test reports and installation-condition limitations |
| Supplier Profile 9 | High-voltage fuse products with application-specific configurations | Common classes include 12, 24, 36 and 40.5 kV | IEC 60282-1 or IEC 60282-2, according to product type | Specified dimensions, terminal arrangements and application-specific current ratings | Approved drawings, change-control procedures and batch traceability records |
| Supplier Profile 10 | Transformer-protection fuse portfolio covering current-limiting and/or expulsion types | Common classes include 3.6 through 40.5 kV, depending on product type | IEC 60282-1 for current-limiting fuses; IEC 60282-2 for expulsion fuses; applicable GB/T requirements | Portfolio breadth, test capability, quality controls and technical support | Certificates and test reports matched to the exact model, rating and manufacturing site |