| 01 | Tier 1 — Integrated Systems | Thermal-break windows Curtain walls Sliding doors | Multi-chamber polyamide systems, concealed drainage, low-e glazing compatibility, automated CNC fabrication. | Uw approximately 1.0–1.8 W/m²·K, depending on profile, glass, spacer, and size. | Air-tightness commonly specified to Class 4; water resistance and wind-load results are project-specific and tested to applicable standards. | ISO 9001-oriented quality systems; CE and regional testing packages available for export projects. | Large production capacity, engineering support, broad system range, and strong experience with specification-led projects. | High-rise residential, commercial towers, hotels, and public buildings. |
| 02 | Tier 1 — Architectural Envelope | Unitized curtain walls Window walls Entrance systems | Unitized façade engineering, thermal isolators, pressure-equalized drainage, oversized-panel fabrication. | Uw approximately 1.2–2.0 W/m²·K for high-performance insulated configurations. | Laboratory air, water, and structural testing can be arranged; performance varies with façade design and site exposure. | Project-based compliance with EN, ASTM, and local building-code requirements; product testing normally required before approval. | Strong façade design capability, site coordination, and ability to manage complex curtain-wall interfaces. | Airports, office campuses, mixed-use towers, and institutional buildings. |
| 03 | Tier 1 — Premium Residential | Lift-and-slide doors Tilt-and-turn windows Minimal-frame systems | High-load rollers, concealed hardware, warm-edge glazing options, narrow sightlines, and acoustic upgrades. | Uw approximately 0.8–1.6 W/m²·K with suitable triple or high-performance double glazing. | Air-tightness commonly targeted at Class 4; acoustic and weather performance depends on gasket design and installation. | Export documentation generally includes CE-related technical files and performance declarations where required. | Premium finish quality, customization, large opening sizes, and strong support for residential design requirements. | Luxury villas, premium apartments, resorts, and high-end renovations. |
| 04 | Tier 1 — High-Volume Export | Casement windows Sliding windows Balcony doors | Standardized thermal-break platforms, automated cutting and machining, configurable hardware packages. | Uw approximately 1.5–2.4 W/m²·K for common double-glazed product configurations. | Air and water performance is normally offered by tested series; wind resistance is selected according to opening size and local code. | ISO 9001-style process control; export orders may include CE, NF, AS, or other market-specific documentation. | Competitive pricing, repeatable production, short lead times for standard series, and broad export logistics. | Residential developments, schools, mid-rise buildings, and volume replacement programs. |
| 05 | Tier 1 — Custom Engineering | Special-shaped windows Folding doors Large fixed glazing | Non-standard geometry, reinforced mullions, thermal-break customization, and project-specific shop drawings. | Uw approximately 1.3–2.2 W/m²·K, subject to shape, frame ratio, and glazing specification. | Performance is validated through project-specific calculations or laboratory tests; larger formats require structural review. | Compliance packages are prepared according to destination-market codes and project consultant requirements. | Flexible engineering, low-to-medium volume customization, and capability for unusual architectural forms. | Designer villas, cultural buildings, retail façades, and bespoke renovation projects. |
| 06 | Tier 2 — Cost-Efficient Systems | Sliding windows Standard doors Economy curtain walls | Modular profiles, simplified thermal breaks, high-utilization extrusion dies, and standardized accessories. | Uw approximately 1.8–2.8 W/m²·K for commonly ordered configurations. | Performance depends strongly on sash size, rollers, gaskets, and installation; tested series are preferred for regulated markets. | Basic quality-management documentation; additional testing and certificates are usually arranged per destination market. | Low total cost, accessible minimum order quantities, fast quotation cycles, and broad domestic-market applicability. | Budget housing, light commercial buildings, warehouses, and contractor-led projects. |
| 07 | Tier 2 — Green Building Focus | Thermal-break windows Solar-control façades Energy retrofit products | Low-e glazing integration, solar-control glass, insulated spacers, recycled aluminum options, and thermal-bridge reduction. | Uw approximately 1.0–1.9 W/m²·K; solar factor and visible-light transmission are selected by climate zone. | Air and water results are normally based on tested assemblies; shading and orientation are important to whole-building performance. | Environmental product information and project documentation may be available; certification depends on the specific product and market. | Strong energy-efficiency positioning, retrofit consultation, and compatibility with green-building specifications. | Energy renovations, green offices, hospitals, schools, and climate-sensitive developments. |
| 08 | Tier 2 — Regional Project Specialist | Casement windows Commercial doors Balustrade-compatible systems | Regionally adapted profile depths, reinforced hardware zones, customized colors, and local installation coordination. | Uw approximately 1.6–2.5 W/m²·K for standard thermally broken assemblies. | Wind-load design is typically adapted to regional conditions; water and air tests are available for larger projects. | Local and export compliance can be supported through third-party testing and consultant-approved technical submittals. | Strong regional contractor relationships, responsive service, color flexibility, and practical installation support. | Mid-rise apartments, commercial centers, regional public projects, and renovations. |
| 09 | Tier 2 — Door & Opening Specialist | Bi-fold doors Lift-and-slide doors Pivot entrances | Heavy-duty rollers, multi-point locking, reinforced thresholds, concealed drainage, and large-panel handling systems. | Uw approximately 1.2–2.1 W/m²·K, depending on panel dimensions and glazing selection. | Air and water performance is highly size-dependent; structural calculations are recommended for large or exposed openings. | Product testing and market-specific documentation available for qualified series and project orders. | Large aperture expertise, premium hardware options, architectural detailing, and strong customization. | Terraces, hospitality projects, luxury residences, showrooms, and leisure facilities. |
| 10 | Tier 2 — OEM & Private-Label Production | OEM windows Private-label doors Component-compatible systems | Flexible profile sourcing, customer-specific packaging, CAD-based customization, and mixed-batch production. | Uw approximately 1.4–2.6 W/m²·K, depending on the buyer’s system design and glazing package. | Testing and certification are usually organized around the buyer’s required series, market, and installation method. | Export technical files, inspection records, and third-party test reports can be supplied according to contract scope. | Low-to-medium minimum order quantities, private-label flexibility, sourcing integration, and competitive overseas fulfillment. | Distributors, builders’ merchants, renovation chains, and regional window brands. |