| 1 | Raintight Compression Connector with Insulated Throat | Electro-galvanized steel body, zinc-plated compression nut, polymer insulated throat | 1/2–2 in NPSM; 14 TPI for 1/2–3/4 in, 11.5 TPI for 1–1 1/2 in, 8 TPI for 2 in | 1/2–2 in EMT | Apply NEC-style fill limits: 53% for one conductor, 31% for two, and 40% for more than two conductors | Up to IP66 when certified and correctly assembled | C3 to C4; suitable for moderate industrial and outdoor exposure with intact coating | Outdoor equipment, wet locations, utility rooms, and industrial installations | Strong environmental sealing with reliable mechanical retention |
| 2 | Aluminum Raintight Compression Connector | Die-cast aluminum body with corrosion-resistant compression components | 1/2–2 in NPSM; common hub sizes include 1/2, 3/4, 1, 1 1/4, 1 1/2, and 2 in | 1/2–2 in EMT | Use the raceway internal area and maintain 53%, 31%, or 40% maximum fill according to conductor count | Up to IP66; some certified assemblies may reach IP67 | C4 to C5-M suitability when the complete assembly is corrosion-resistant and properly maintained | Coastal infrastructure, wastewater facilities, marine-adjacent buildings, and exposed outdoor areas | Low weight and good resistance to atmospheric corrosion |
| 3 | Standard Compression Connector | Steel body with zinc or electro-galvanized finish; insulated throat optional | 1/2–2 in NPSM, matched to the box knockout and connector trade size | 1/2–2 in EMT | Compatible with standard raceway calculations: 53% single-conductor, 31% two-conductor, and 40% multi-conductor fill | Typically IP40 or enclosure-dependent; not intended for wet locations unless specifically certified | C2 to C3 for dry indoor or mildly industrial environments | Commercial interiors, control cabinets, panelboards, and protected equipment rooms | More secure and vibration-resistant than basic set-screw designs |
| 4 | Set-Screw Connector with Insulated Throat | Zinc-plated steel body, hardened set screw, thermoplastic throat insert | 1/2–1 in NPSM; typical sizes use 14 TPI for 1/2 and 3/4 in hubs | 1/2–1 in EMT | Conductor fill remains governed by raceway area: 53% for one, 31% for two, and 40% for more than two conductors | Normally IP40 or lower unless installed inside a suitably rated enclosure | C1 to C2 for dry, clean indoor locations | Indoor branch circuits, lighting systems, and general commercial wiring | Cost-effective installation with reduced conductor abrasion risk |
| 5 | Aluminum Set-Screw Connector | Die-cast aluminum body with plated or stainless set screw | 1/2–2 in NPSM; select the hub size to match the knockout diameter | 1/2–2 in EMT | Use the actual EMT internal diameter for fill calculation and observe the 53%/31%/40% limits | Typically IP40 to IP54 depending on enclosure and installation details | C3; suitable for humid or mildly corrosive areas when galvanic compatibility is controlled | Lightweight assemblies, elevated cable tray transitions, and protected outdoor equipment | Reduced fitting weight with good handling during field installation |
| 6 | 90-Degree Compression Connector | Galvanized steel or aluminum body with compression nut and sealing ring | 1/2–1 1/2 in NPSM; angle geometry varies by trade size | 1/2–1 1/2 in EMT | Conduit fill is calculated through the connected EMT; conductor count limits remain 53%, 31%, and 40% | Up to IP65 when supplied with a sealing gasket and certified for the intended enclosure | C3 to C4 depending on body material, plating, and gasket durability | Compact panels, tight wall spaces, motor-control equipment, and directional changes | Reduces bend-space requirements while maintaining a sealed transition |
| 7 | EMT-to-Flexible Metal Conduit Transition Connector | Zinc-plated steel or malleable iron body with threaded adapter and clamp section | 1/2–1 in NPSM on the EMT side; flexible conduit connection size must match the clamp or thread | 1/2–1 in EMT with compatible flexible metal conduit | Calculate fill for the smallest internal raceway section; use 40% maximum for more than two conductors | Typically IP40; higher ratings require a sealed transition design and certified installation | C2 to C3 for indoor commercial and light industrial applications | Vibration-prone machinery, equipment connections, and short flexible drops | Provides a practical transition between rigid EMT and flexible wiring sections |
| 8 | Insulated-Throat Set-Screw Connector for Large EMT | Heavy-duty zinc-plated steel with polymer insulating throat and locking set screw | 1 1/4–4 in NPSM; common large sizes include 1 1/4, 1 1/2, 2, 2 1/2, 3, and 4 in | 1 1/4–4 in EMT | Large-raceway fill must be calculated from the actual internal diameter; maximum fill is normally 40% for more than two conductors | Normally IP40 unless protected by a rated enclosure | C2 to C3 with suitable coating and indoor or sheltered installation | Large feeder circuits, service rooms, industrial distribution, and high-cable-count runs | Supports larger raceways while protecting cable jackets at the entry point |
| 9 | Heavy-Duty Raintight Compression Connector | Malleable iron or heavy-gauge steel body with plated compression hardware and elastomeric seal | 1/2–4 in NPSM; verify thread pitch and knockout compatibility for larger sizes | 1/2–4 in EMT | Use 53% for one conductor, 31% for two, and 40% for more than two conductors; also check pulling and bending space | Up to IP66 when the gasket, conduit, enclosure, and installation are all certified together | C4; higher environments require stainless or specialized corrosion-resistant construction | Heavy industrial plants, outdoor distribution, transport facilities, and exposed service connections | High mechanical strength and dependable sealing for demanding installations |
| 10 | Stainless-Steel Compression Connector | Stainless steel body, nut, and hardware; insulated throat available in selected sizes | 1/2–2 in NPSM; select the thread size to match the enclosure knockout and EMT trade size | 1/2–2 in EMT | Apply the appropriate raceway fill percentage and confirm that the connector does not reduce the required cable bending space | Up to IP66 or IP67 when supplied as a certified sealed assembly | C5-M suitability for severe marine or chemical exposure, subject to material grade and certification | Food-processing areas, chemical facilities, coastal plants, and high-humidity industrial sites | Excellent corrosion resistance and long service life in aggressive environments |